Injection Hose Installation

INJECTION HOSE INSTALLATION IN EXETER

Free site survey, a written diagnosis and a fixed, itemised quotation — for concrete structures requiring crack repair systems across the Exeter area

Durable, long-life results on concrete structures requiring crack repair systems across Exeter, using high-performance resin delivery systems products and a written specification you can hold us to.

How the Work Is Carried Out

Works on concrete structures requiring crack repair systems are phased so the building keeps operating: areas are handed over in sections, access equipment is moved rather than left standing, and fast-cure materials are used where the programme is tight. You get a method statement and a risk assessment before anyone arrives on site.

Areas We Cover

• Sowton
• Marsh Barton
• Peninsula Park
• Pynes Hill
• Woodwater Park
• Matford
• Exminster
• Alphington
• Topsham
• Digby
• Pinhoe
• Whipton
• Countess Wear
• St Thomas
• Heavitree

And across Devon

Why Choose MPS?

Established 2013, with 25+ years' combined team experience
Sika-approved contractor status
Fast-response service across Devon
Minimal disruption to operations

Injection Hose Installation Methods & Systems

We install specialist injection hose systems for crack repair, curtain grouting, and structural strengthening using resin injection technology.

Passive Injection Hoses

Pre-installed hose systems embedded in cracks that activate when water pressure occurs, automatically injecting resin to seal leaks without manual intervention in inaccessible areas.

Active Injection Systems

Pressure-controlled injection hose networks for systematic crack sealing, allowing staged resin injection into multiple cracks from a single pump system with precise flow control.

Curtain Grouting Hoses

Tube-à-manchette (TAM) systems for creating waterproof resin curtains in soil or rock, used for tunnel waterproofing, dam repairs, and foundation stabilisation applications.

Crack Stitching Integration

Combined crack stitching and injection hose systems that structurally reinforce cracks while simultaneously sealing them with epoxy or polyurethane resins.

Flexible Resin Delivery

Multi-port injection hose manifolds allowing sequential or simultaneous resin delivery to multiple crack locations, optimising injection efficiency in large-scale repairs.

Monitoring & Testing

Pressure monitoring systems integrated with injection hoses to verify complete resin penetration, detect flow resistance, and confirm structural bond quality during injection.

Injection Hose Installation Process

01

Crack Mapping & Planning

Cracks are mapped, depth assessed, and injection hose layout designed to ensure complete resin coverage. Hose spacing and port locations determined based on crack characteristics.

02

Hose Installation

Injection hoses are surface-mounted along crack lines or embedded into drilled channels, secured with quick-set adhesive, and connected to injection ports or manifolds.

03

Resin Injection

Low-viscosity epoxy or polyurethane resin is pressure-injected through hoses, flowing through valves or porous sections into cracks until complete saturation is achieved.

04

Curing & Removal

After resin cures (24-48 hours), surface-mounted hoses are cut flush, embedded hoses remain in place, and surfaces are finished to match existing concrete appearance.

Frequently Asked Questions

When is injection hose installation necessary?

Injection hoses are used for deep cracks, inaccessible locations, cracks requiring systematic multi-point injection, curtain grouting applications, or where passive systems that activate automatically when water pressure occurs are required. They're essential for complex structural crack repairs where standard surface injection may be insufficient.

What's the advantage of injection hoses over standard crack injection?

Injection hoses allow resin delivery deep into cracks from multiple points, ensuring complete penetration in thick sections. They enable systematic injection along entire crack lengths, work in inaccessible areas, and passive systems can seal future water ingress automatically without further intervention.

How much does injection hose installation cost?

Costs vary based on crack length, depth, accessibility, hose type (passive/active), and resin volumes required. Injection hose systems typically cost £800-£2,500 for residential crack repairs, with larger commercial projects priced per linear metre. The additional cost over standard injection is justified by superior penetration and reliability.

Can injection hoses seal cracks that are still moving?

Yes, when using flexible polyurethane resins through injection hoses, the system can accommodate minor crack movement while maintaining waterproof integrity. Passive injection hoses are particularly effective as they automatically inject resin when crack movement causes water pressure, creating self-healing characteristics.

Are injection hoses left in the structure permanently?

This depends on installation method. Surface-mounted hoses are typically removed after injection and cut flush. Embedded hoses in drilled channels or passive systems remain in place permanently, encapsulated in resin and invisible once surfaces are finished. Both approaches provide permanent structural crack sealing.

Standards, Credentials & Documented Work

What you can check before appointing us.

Standards that govern this work

  • BS 8102:2022 — detailing of construction joints in Type B (structurally integral) protection
  • BS EN 1504-5 — the injection resins and grouts used to seal the hose after the pour

Who does the work

MPS Concrete Solutions was founded in 2013 and works from Gamlingay, Cambridgeshire (SG19 3JW). Our operatives hold NVQs in resin and grout injection, CSCS, SSSTS and SMSTS cards, and PASMA and MEWP (3a/3b) training, and are confined-space trained.

  • Constructionline Gold member; SSIP accredited
  • UKAS-accredited certification to ISO 9001, ISO 14001 and ISO 45001
  • Concrete Repair Association (CRA) member
  • Sika-specified applicator

How we get to Exeter

From our yard at Gamlingay in South Cambridgeshire, Exeter is two and a half to four hours. Planned as multi-day visits with plant and materials delivered to site, so the phasing is agreed at survey stage rather than improvised later.

We say this plainly because it shows up in the price. Mobilisation, access plant and preparation equipment are largely fixed costs, so a single small repair a long way from base carries a much higher rate per square metre than the same work next door to us, or the same work bundled with other defects on one visit. If you have more than one problem on the site, it is worth having them all surveyed at once.

Reviewed by Jerry Blears, Director (LinkedIn), MPS Concrete Solutions. Last reviewed October 2026.

Related injection hose installation projects

Canary Wharf, London Hydrophilic resin injection to stop active water ingress at the abutments of a bascule bridge beside the Jubilee Line exclusion zone.

All case studies →

Send Us Photographs and We'll Tell You What It Is

If it needs a site visit, the survey is free. You get the findings, the cause, and an itemised quotation in writing — the documentation your engineer, insurer or managing agent needs to authorise the works.